Nume | Scop | Expirare |
---|---|---|
show_cookie_message | Ukládá informaci o potřebě zobrazení cookie lišty | 1 year |
__zlcmid | This Cookie is used to store the visitor’s identity across visits and the visitor’s preference to disable our live chat feature. | 1 year |
__cfruid | This cookie is a part of the services provided by Cloudflare - Including load-balancing, deliverance of website content and serving DNS connection for website operators. | session |
_auth | Ensures visitor browsing-security by preventing cross-site request forgery. This cookie is essential for the security of the website and visitor. | 1 year |
csrftoken | Helps prevent Cross-Site Request Forgery (CSRF) attacks. | 1 year |
PHPSESSID | Preserves user session state across page requests. | session |
rc::a | This cookie is used to distinguish between humans and bots. This is beneficial for the website, in order to make valid reports on the use of their website. | persistent |
rc::c | This cookie is used to distinguish between humans and bots. | session |
AWSALBCORS | Registers which server-cluster is serving the visitor. This is used in context with load balancing, in order to optimize user experience. | 6 days |
18plus_allow_access# | unknown | |
18plus_cat# | unknown | |
bs_slide_menu | unknown | |
left_menu | unknown |
NOUTĂŢI
CONTACT
Introducere »GEMAK Vane hidraulice»VANA HIDRAULICA UNI GEMAK»ELECTROVENTIL HIDRAULIC GEMAK » Electroventil Normal Inchis Incendiu S1080 DN 65
S1080 Ventil electromagnetic Normal Inchis
Caracteristici Generale / General Specifications
Model / Type : S1080/S1082
Dimensiuni / Dimensions : 2”- 10” (DN 50… 300)
Presiune nominală / Nominal Pressure: 16 bar
Temperatură de lucru / Working Temperature: 4…+70°C
Flanşe / Flanges: EN 1092 PN 16
Tensiune / Voltage: 220VAC, 24VAC/VDC, 12 VAC/VDC
Standarde / Standards
Certificări / Certificate : CE
Ventile electromagnetice de tip normal închis / normal deschis se utilizează în toate aplicaţiile în care se vehiculează apă rece, curată, în special rețelele de alimentare cu apă potabilă și cele de stins incendii pentru controlul alimentărilor cu apă și al rezervoarelor de stocare. Solenoid valves normally closed / normally open are used for all lines with cold, clean water, especially potable water and fire protection networks to control the water filling of pipes and water tanks.
Caracteristici Generale/ General Characteristics
Design nou, trecere totală, pierderi de presiune reduse
New design, full bore, low pressure loses
Electroventilul normal închis NC rămâne închis până la aplicarea tensiunii de comandă la electroventilul pilot și va păstra poziția deschis cât timp această tensiune se va menține aplicată pe bobina electroventilului pilot de comandă; întreruperea tensiunii de comandă duce la închiderea electroventilului. Poziția ON/OFF - comanda ansamblului se face prin acționarea unui electroventil pilot cu trei căi cu corp din alamă de tip normal deschis sau normal închis.
The Normally Closed NC solenoid valve remain in closed position till will apply power on the solenoid pilot valve and will keep the open position as long as you will maintain the power on the coil of the pilot; shutting down the power will re-establish the closed position of the valve. The ON/OFF position off the solenoid valve is controlled through a solenoid pilot valve NO or NC.
Electroventilul normal deschis NO rămâne deschis până la aplicarea tensiunii de comandă la electroventilul pilot și va păstra poziția închis cât timp această tensiune se va menține aplicată pe bobina electroventilului pilot de comandă; întreruperea tensiunii de comandă duce la deschiderea electroventilului
The Normally Open NO solenoid valve remain in open position till will apply power on the solenoid pilot valve and will keep the closed position as long as you will maintain the power on the coil of the pilot; shutting down the power will re-establish the open position of the valve.
Temperatura de lucru -10 oC … +70 oC; Nu se utilizează pentru fluide periculoase din grupa 1 PED
Working temperature -10 oC … +70 oC; Do not use for fluids on group 1 acc. PED
Cu servocomandă, necesită o presiune diferenţială minimă la intrare de 1 sau 1,5 bar. Atenție la montaj! Sensul de curgere este marcat pe corp! Nerespectarea acestuia face vana nefuncțională!
Servo-actuated valve, request a minimum differential pressure of 1 or 1.5 bar. Attention at the mounting position! One arrow indicating the flow through the valve is marked on the body! Changing this flow direction will make the valve to malfunction!
Sunt prevăzute cu selector mecanic al modului de funcționare cu 3 poziții: închis-deschis-automat ce are și rol de siguranță – permite deschiderea (pentru cele normal închise) sau închiderea (cele normal deschise) manuală a vanei în condițiile căderii accidentale a alimentării cu curent electric. Selectarea modului automat (AUTO) permite comanda vanei în funcție de starea / comanda electroventilului pilot.
Solenoid valves are equiped with a mechanical 3 way valve which select the function: close-open-auto; it is a safety device to permit the opening (for NC type) or the closing (for NO type) of the whole valve when power is down. By selecting automatic mode (AUTO) the solenoid valve is opening or closing by actuating the pilot valve.
Gamă largă de presiuni şi debite de lucru, ideale pentru automatizări în aplicaţii diverse
Large range of working pressures and flow, suitable for automation in large applications range.
Fabricate conform cerinţelor PED 2014/68/EU şi LVD 2006/95/EC.
Manufactured acc. PED2014/68/EU and LVD 2006/95/EC
Siguranţă în funcţionare, rezistenţă la coroziune (corp vopsit epoxy și racorduri din cupru), timp de viaţă ridicat, calitate şi performanţă foarte bune.
Safety in function, good resistance against corrosion (epoxy paint and copper fittings), long lifetime, quality and very good performance
Subansamble / Main parts
Nr |
Denumire / Name |
1 |
Corp cu flanșe / Flanged main body |
2 |
Electroventil pilot / Solenoid pilot valve |
3 |
Selector mecanic de poziție / 3 way mechanical valve |
Materiale Componente / Material Specifications
Nr |
Denumire Componentă / Part Name |
Material / Material |
1 |
Corp/ Body |
Fontă / Cast iron |
2 |
Capac / Bonnet |
Fontă / Cast iron |
3 |
Ghidaj arc / Spring guide |
Poliamidă / Poliamide |
4 |
Arc / Spring |
Oţel de arc / Spring steel |
5 |
Membrană/ Membrane |
NBR |
Funcționare / Function
Electroventilul normal închis NC rămâne închis până la aplicarea tensiunii de comandă la electroventilul pilot și va păstra poziția deschis cât timp această tensiune se va menține aplicată pe bobina electroventilului pilot de comandă; întreruperea tensiunii de comandă duce la închiderea electroventilului.
The Normally Closed NC solenoid valve remain in closed position till will apply power on the solenoid pilot valve and will keep the open position as long as you will maintain the power on the coil of the pilot; shutting down the power will re-establish the closed position of the valve.
Electroventilul normal deschis NO rămâne deschis până la aplicarea tensiunii de comandă la electroventilul pilot și va păstra poziția închis cât timp această tensiune se va menține aplicată pe bobina electroventilului pilot de comandă; întreruperea tensiunii de comandă duce la deschiderea electroventilului
The Normally Open NO solenoid valve remain in open position till will apply power on the solenoid pilot valve and will keep the closed position as long as you will maintain the power on the coil of the pilot; shutting down the power will re-establish the open position of the valve.
Caracteristici electrice / Electrical characteristics
Funcționare continuă: ED 100% |
Continuous Duty: 100% |
Clasa de izolare bobină: H 180oC IEC85 |
Coil insulation class 180 oC IEC85 |
Temperatură mediu ambient: -10…+60 oC Fără posibilitate de îngheț! |
Ambient temperature -10…60 oC NO FROST! |
Clasa de protecție: IP65 EN60529 |
Protection class IP65 EN6529
|
Siguranţă electrică IEC 335 |
Electrical safety IEC 335 |
Conector ISO 4400 / EN 175301-803 forma A (cablu 6-8 mm) |
Connector ISO 4400 / EN 175301-803 Form A, (Ø6-8 mm) |
Conexiune cu 3 poli DIN 46340 (DIN 43650) |
Electrical plug connection DIN 46340 3– Poles Connector(DIN43650) |
Toleranţa tensiunii de comandă: curent alternativ CA (-15%...+10%) curent continuu CC (-5%...+10%)
|
Voltages Tolerance AC (-15%...+10%) DC (-5%...+10%)
|
Tensiune de comandă 12V, 24V, 48V (CC și CA), 110, 230 CA |
Voltage 12V, 24V, 48V (DC & AC), 110, 230 AC |
Caracteristici tehnice / Technical characteristics
Timp de deschidere: 0,4…1,6 secunde; Timp de închidere: 1…2 secunde
Opening time: 0.4…1.6 seconds; Closing time 1…2 seconds
Presiune maximă de lucru: 16 bar
Maximum working pressure: 16 bar
Temperatură maximă de lucru: 70oC
Maximum working temperature 70oC
Temperatură minimă de lucru: 4oC (fără îngheț)
Minimum working temperature 4oC (no frost)
Flanșe de prindere: PN 16 EN 1092
Connection flanges: PN 16 EN 1092
Dimensiuni de gabarit / Overall Dimensions
Montaj / Mounting
Orizontală cu pilotul de comandă în sus (preferabil); se poate monta și vertical în instalații cu fluide curate.
Nu este recomandat montajul cu bobina în jos deoarece rugina sau alte impurităţi se pot depune şi împiedică mişcarea miezului la comanda bobinei!
Horizontally with pilot solenoid upward (mostly); can be vertically mounted for filtered fluids. In solenoid valve assembly, please be careful that the coil should not be at the lower part when conducting assembly. Otherwise, the core in the hive shall be affected by the residuals and rusts accumulated in time and prevent the coil to move the core.
Verificaţi ca tensiunea de alimentare a circuitului bobinei să corespundă cu tensiunea inscripţionată pe corpul bobinei! Tensiune prea mare sau prea mică poate deteriora bobina sau împiedică închiderea - deschiderea ventilului. În aplicaţii critice sau circuite electronice bobina trebuie comandată de către un releu!
Every coil should operate under the voltage limits written on it. The higher or lower voltages may cause damages to the coils or not to run. In critical applications like electronic cards coil must be controlled through a RELAY.
Conectarea cablurilor la conectorul bobinei pentru curent alternativ CA fază şi nul sau pentru curent continuu CC tensiunile pozitivă (+) şi negativă (-) se face la bornele 1 şi 2. Împământarea se leagă la borna 4. Cablul de împământare este cel de culoare galben-verde
When connecting the cable ends to connector, for AC voltages, the phaseneutral ends, and for the DC voltages, the positive (+) and negative (-) terminals should be connected to the number 1 and 2 connections. The earth terminal should be connected with the grounding conductor in the cable, if any. The grounding conductor is the yellow-green wire
Cablul conectat la conector nu trebuie îndoit și răsucit pentru a evita consecințele care ar putea apărea din cauza contactelor slăbite sau a scurt circuitelor apărute în urma strivirii. Cablul trebuie să fie poziționat vertical, ca în figură. De asemenea, răsucirile la capătul de intrare în conector pot permite umidității să pătrundă în conector. Pentru prevenirea umidității sau a scurgerii apei în conector, diametrul cablului trebuie să fie de o mărime care să permită etanșeizarea. Nu uitaţi de garnitura de cauciuc ce etanşează montajul conector-bobină!
Any bending or twisting should not be found with the cable connected to the connector in order to avoid any deficits resulting from any loose contact or shortcircuit due to any crush. The cable should be uprights as shown in the figure. In addition, the twists in the connector input may allow humidity to penetrate into the connector. In order to prevent humidity or water to leak into the socket, the diameter of the cable should be in a size that provides sealing
Bobina se poate încinge într-o funcţionare îndelungată, atingerea ei cu mâna neprotejată poate cauza arsuri! Aceeaşi avertizare în cazul în care prin ventil circulă fluide fierbinţi ceea ce duce la încălzirea corpului! Folosiţi echipament de protecţie adecvat!
The coil gets hot in long-term operations. The hot coil may cause burnt if touched. Same warning for hot fluids! Use protection equipment!
Utilizaţi filtre pentru reţinerea impurităţilor! Impurităţile din fluid, rugina, stropii de sudură, resturile de polietilenă sau alte resturi rămase de la asamblarea conductelor pot bloca acţionarea miezului la apariţia comenzii electrice şi pot arde bobina. Aceleaşi reziduuri şi impurităţi pot deteriora rapid membrana ventilului. Lipsa filtrelor înainte de electroventil duce la pierderea garanţiei în cazul defectării!!!
Filters should be used for required fluids. The residuals and rusts accumulated in the valve may cause inconveniency for the coil to pull the core. This inconveniency may cause burn of the core. Missing of strainers will affect the guarantee of the product!
Pierderi de presiune / Pressure loss
Exemplu de utilizare: umplere rezervor / Application – level control
Consum din rezervor / Consumption from tank
Când s-a atins nivelul minim în rezervor vana se deschide pentru a reumple complet /
When minimum level is reached the valve open to fill the tank
Când se atinge nivelul maxim în rezervor vana se închide /
When maximum level is obtained in tank the valve close
Ne rezervam dreptul de a modifica datele tehnice în funcţie de îmbunătăţirile aduse produsului/ We reserve the right to modify any data due to continue improvement
Caracteristici Generale / General Specifications
Model / Type : S1080/S1082
Dimensiuni / Dimensions : 2”- 10” (DN 50… 300)
Presiune nominală / Nominal Pressure: 16 bar
Temperatură de lucru / Working Temperature: 4…+70°C
Flanşe / Flanges: EN 1092 PN 16
Tensiune / Voltage: 220VAC, 24VAC/VDC, 12 VAC/VDC
Standarde / Standards
Certificări / Certificate : CE
Ventile electromagnetice de tip normal închis / normal deschis se utilizează în toate aplicaţiile în care se vehiculează apă rece, curată, în special rețelele de alimentare cu apă potabilă și cele de stins incendii pentru controlul alimentărilor cu apă și al rezervoarelor de stocare. Solenoid valves normally closed / normally open are used for all lines with cold, clean water, especially potable water and fire protection networks to control the water filling of pipes and water tanks.
Caracteristici Generale/ General Characteristics
Design nou, trecere totală, pierderi de presiune reduse
New design, full bore, low pressure loses
Electroventilul normal închis NC rămâne închis până la aplicarea tensiunii de comandă la electroventilul pilot și va păstra poziția deschis cât timp această tensiune se va menține aplicată pe bobina electroventilului pilot de comandă; întreruperea tensiunii de comandă duce la închiderea electroventilului. Poziția ON/OFF - comanda ansamblului se face prin acționarea unui electroventil pilot cu trei căi cu corp din alamă de tip normal deschis sau normal închis.
The Normally Closed NC solenoid valve remain in closed position till will apply power on the solenoid pilot valve and will keep the open position as long as you will maintain the power on the coil of the pilot; shutting down the power will re-establish the closed position of the valve. The ON/OFF position off the solenoid valve is controlled through a solenoid pilot valve NO or NC.
Electroventilul normal deschis NO rămâne deschis până la aplicarea tensiunii de comandă la electroventilul pilot și va păstra poziția închis cât timp această tensiune se va menține aplicată pe bobina electroventilului pilot de comandă; întreruperea tensiunii de comandă duce la deschiderea electroventilului
The Normally Open NO solenoid valve remain in open position till will apply power on the solenoid pilot valve and will keep the closed position as long as you will maintain the power on the coil of the pilot; shutting down the power will re-establish the open position of the valve.
Temperatura de lucru -10 oC … +70 oC; Nu se utilizează pentru fluide periculoase din grupa 1 PED
Working temperature -10 oC … +70 oC; Do not use for fluids on group 1 acc. PED
Cu servocomandă, necesită o presiune diferenţială minimă la intrare de 1 sau 1,5 bar. Atenție la montaj! Sensul de curgere este marcat pe corp! Nerespectarea acestuia face vana nefuncțională!
Servo-actuated valve, request a minimum differential pressure of 1 or 1.5 bar. Attention at the mounting position! One arrow indicating the flow through the valve is marked on the body! Changing this flow direction will make the valve to malfunction!
Sunt prevăzute cu selector mecanic al modului de funcționare cu 3 poziții: închis-deschis-automat ce are și rol de siguranță – permite deschiderea (pentru cele normal închise) sau închiderea (cele normal deschise) manuală a vanei în condițiile căderii accidentale a alimentării cu curent electric. Selectarea modului automat (AUTO) permite comanda vanei în funcție de starea / comanda electroventilului pilot.
Solenoid valves are equiped with a mechanical 3 way valve which select the function: close-open-auto; it is a safety device to permit the opening (for NC type) or the closing (for NO type) of the whole valve when power is down. By selecting automatic mode (AUTO) the solenoid valve is opening or closing by actuating the pilot valve.
Gamă largă de presiuni şi debite de lucru, ideale pentru automatizări în aplicaţii diverse
Large range of working pressures and flow, suitable for automation in large applications range.
Fabricate conform cerinţelor PED 2014/68/EU şi LVD 2006/95/EC.
Manufactured acc. PED2014/68/EU and LVD 2006/95/EC
Siguranţă în funcţionare, rezistenţă la coroziune (corp vopsit epoxy și racorduri din cupru), timp de viaţă ridicat, calitate şi performanţă foarte bune.
Safety in function, good resistance against corrosion (epoxy paint and copper fittings), long lifetime, quality and very good performance
Subansamble / Main parts
Nr |
Denumire / Name |
1 |
Corp cu flanșe / Flanged main body |
2 |
Electroventil pilot / Solenoid pilot valve |
3 |
Selector mecanic de poziție / 3 way mechanical valve |
Materiale Componente / Material Specifications
Nr |
Denumire Componentă / Part Name |
Material / Material |
1 |
Corp/ Body |
Fontă / Cast iron |
2 |
Capac / Bonnet |
Fontă / Cast iron |
3 |
Ghidaj arc / Spring guide |
Poliamidă / Poliamide |
4 |
Arc / Spring |
Oţel de arc / Spring steel |
5 |
Membrană/ Membrane |
NBR |
Funcționare / Function
Electroventilul normal închis NC rămâne închis până la aplicarea tensiunii de comandă la electroventilul pilot și va păstra poziția deschis cât timp această tensiune se va menține aplicată pe bobina electroventilului pilot de comandă; întreruperea tensiunii de comandă duce la închiderea electroventilului.
The Normally Closed NC solenoid valve remain in closed position till will apply power on the solenoid pilot valve and will keep the open position as long as you will maintain the power on the coil of the pilot; shutting down the power will re-establish the closed position of the valve.
Electroventilul normal deschis NO rămâne deschis până la aplicarea tensiunii de comandă la electroventilul pilot și va păstra poziția închis cât timp această tensiune se va menține aplicată pe bobina electroventilului pilot de comandă; întreruperea tensiunii de comandă duce la deschiderea electroventilului
The Normally Open NO solenoid valve remain in open position till will apply power on the solenoid pilot valve and will keep the closed position as long as you will maintain the power on the coil of the pilot; shutting down the power will re-establish the open position of the valve.
Caracteristici electrice / Electrical characteristics
Funcționare continuă: ED 100% |
Continuous Duty: 100% |
Clasa de izolare bobină: H 180oC IEC85 |
Coil insulation class 180 oC IEC85 |
Temperatură mediu ambient: -10…+60 oC Fără posibilitate de îngheț! |
Ambient temperature -10…60 oC NO FROST! |
Clasa de protecție: IP65 EN60529 |
Protection class IP65 EN6529
|
Siguranţă electrică IEC 335 |
Electrical safety IEC 335 |
Conector ISO 4400 / EN 175301-803 forma A (cablu 6-8 mm) |
Connector ISO 4400 / EN 175301-803 Form A, (Ø6-8 mm) |
Conexiune cu 3 poli DIN 46340 (DIN 43650) |
Electrical plug connection DIN 46340 3– Poles Connector(DIN43650) |
Toleranţa tensiunii de comandă: curent alternativ CA (-15%...+10%) curent continuu CC (-5%...+10%)
|
Voltages Tolerance AC (-15%...+10%) DC (-5%...+10%)
|
Tensiune de comandă 12V, 24V, 48V (CC și CA), 110, 230 CA |
Voltage 12V, 24V, 48V (DC & AC), 110, 230 AC |
Caracteristici tehnice / Technical characteristics
Timp de deschidere: 0,4…1,6 secunde; Timp de închidere: 1…2 secunde
Opening time: 0.4…1.6 seconds; Closing time 1…2 seconds
Presiune maximă de lucru: 16 bar
Maximum working pressure: 16 bar
Temperatură maximă de lucru: 70oC
Maximum working temperature 70oC
Temperatură minimă de lucru: 4oC (fără îngheț)
Minimum working temperature 4oC (no frost)
Flanșe de prindere: PN 16 EN 1092
Connection flanges: PN 16 EN 1092
Dimensiuni de gabarit / Overall Dimensions
Montaj / Mounting
Orizontală cu pilotul de comandă în sus (preferabil); se poate monta și vertical în instalații cu fluide curate.
Nu este recomandat montajul cu bobina în jos deoarece rugina sau alte impurităţi se pot depune şi împiedică mişcarea miezului la comanda bobinei!
Horizontally with pilot solenoid upward (mostly); can be vertically mounted for filtered fluids. In solenoid valve assembly, please be careful that the coil should not be at the lower part when conducting assembly. Otherwise, the core in the hive shall be affected by the residuals and rusts accumulated in time and prevent the coil to move the core.
Verificaţi ca tensiunea de alimentare a circuitului bobinei să corespundă cu tensiunea inscripţionată pe corpul bobinei! Tensiune prea mare sau prea mică poate deteriora bobina sau împiedică închiderea - deschiderea ventilului. În aplicaţii critice sau circuite electronice bobina trebuie comandată de către un releu!
Every coil should operate under the voltage limits written on it. The higher or lower voltages may cause damages to the coils or not to run. In critical applications like electronic cards coil must be controlled through a RELAY.
Conectarea cablurilor la conectorul bobinei pentru curent alternativ CA fază şi nul sau pentru curent continuu CC tensiunile pozitivă (+) şi negativă (-) se face la bornele 1 şi 2. Împământarea se leagă la borna 4. Cablul de împământare este cel de culoare galben-verde
When connecting the cable ends to connector, for AC voltages, the phaseneutral ends, and for the DC voltages, the positive (+) and negative (-) terminals should be connected to the number 1 and 2 connections. The earth terminal should be connected with the grounding conductor in the cable, if any. The grounding conductor is the yellow-green wire
Cablul conectat la conector nu trebuie îndoit și răsucit pentru a evita consecințele care ar putea apărea din cauza contactelor slăbite sau a scurt circuitelor apărute în urma strivirii. Cablul trebuie să fie poziționat vertical, ca în figură. De asemenea, răsucirile la capătul de intrare în conector pot permite umidității să pătrundă în conector. Pentru prevenirea umidității sau a scurgerii apei în conector, diametrul cablului trebuie să fie de o mărime care să permită etanșeizarea. Nu uitaţi de garnitura de cauciuc ce etanşează montajul conector-bobină!
Any bending or twisting should not be found with the cable connected to the connector in order to avoid any deficits resulting from any loose contact or shortcircuit due to any crush. The cable should be uprights as shown in the figure. In addition, the twists in the connector input may allow humidity to penetrate into the connector. In order to prevent humidity or water to leak into the socket, the diameter of the cable should be in a size that provides sealing
Bobina se poate încinge într-o funcţionare îndelungată, atingerea ei cu mâna neprotejată poate cauza arsuri! Aceeaşi avertizare în cazul în care prin ventil circulă fluide fierbinţi ceea ce duce la încălzirea corpului! Folosiţi echipament de protecţie adecvat!
The coil gets hot in long-term operations. The hot coil may cause burnt if touched. Same warning for hot fluids! Use protection equipment!
Utilizaţi filtre pentru reţinerea impurităţilor! Impurităţile din fluid, rugina, stropii de sudură, resturile de polietilenă sau alte resturi rămase de la asamblarea conductelor pot bloca acţionarea miezului la apariţia comenzii electrice şi pot arde bobina. Aceleaşi reziduuri şi impurităţi pot deteriora rapid membrana ventilului. Lipsa filtrelor înainte de electroventil duce la pierderea garanţiei în cazul defectării!!!
Filters should be used for required fluids. The residuals and rusts accumulated in the valve may cause inconveniency for the coil to pull the core. This inconveniency may cause burn of the core. Missing of strainers will affect the guarantee of the product!
Pierderi de presiune / Pressure loss